CFFFY - BIG BEAM L6100
- MSDS: CFFFY
- Manufacturer: TELEDYNE BATTER PRODUCTS TELEDYNE INC COMPANY
- Product Name: BIG BEAM L6100
- National Stock Number: 6140-01-006-5293
Product Identification
Product ID:BIG BEAM L6100
MSDS Date:02/01/1997
FSC:6140
NIIN:01-006-5293
MSDS Number: CFFFY
Responsible Party
REDLANDS, CA 92373
US
Emergency Phone: 800-535-5053 INFO TRAC
Info Phone: 714-793-3131
Preparer: ROBIN J. FRIED
Cage: 84375
Contractor
Telephone: 909-793-3131
Cage: 84375
Ingredients
LEAD (SARA 313) (CERCLA)
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: <94%
OSHA PEL SEE 1910.1025
ACGIH TLV: 0.05MG/M3, A3; 9596
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
SULFURIC ACID (SARA 302/313) (CERCLA)
CAS: 7664-93-9
RTECS: WS5600000
Fraction By Weight: <58%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3/3 STEL; 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ANTIMONY (SARA 313) (CERCLA)
CAS: 7440-36-0
RTECS: CC4025000
Fraction By Weight: <0.4%
OSHA PEL 0.5 MG/M3
ACGIH TLV: 0.5 MG (SB)/M3; 9596
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ARSENIC (SARA 313) (CERCLA)
CAS: 7440-38-2
RTECS: CG0525000
Fraction By Weight: <0.1%
OSHA PEL SEE 1910.1018
ACGIH TLV: 0.01 MG/M3, A1; 9596
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
BARIUM SULFATE
CAS: 7727-43-7
RTECS: CR0600000
Fraction By Weight: <0.4%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9596
CALCIUM COMPOUNDS AS CALCIUM METAL
CAS: 7440-70-2
RTECS: EV8040000
Fraction By Weight: <0.2%
CARBON BLACK EXTRACTS
CAS: 1333-86-4
RTECS: FF5800000
Fraction By Weight: <0.1%
OSHA PEL 3.5 MG/M3
ACGIH TLV: 3.5 MG/M3; 9596
NICKEL SULFATE (SARA 313) (CERCLA)
CAS: 7786-81-4
RTECS: QR9350000
Fraction By Weight: <0.1%
OSHA PEL 1 MG(NI)/M3
ACGIH TLV: 0.1 MG(NI)/M3; 9596
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
TIN COMPOUNDS AS TIN
CAS: 7440-31-5
RTECS: XP7320000
Fraction By Weight: <0.3%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9596
Hazards
LD50 LC50 Mixture:LD50 (ORAL RAT) IS 2140 MG/KG (H2SO4)
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SULFURIC ACID MAY CAUSE IRRITATION TO
THE EYES, NOSE AND THROAT. DIFFICULTY IN BREATHING MAY BE
EXPERIENCED. ACID SPLASHED IN EYES OR ON SKIN MAY CAUSE BURNS OR
IRRITATION. REPEATED OR PROLONGED EXPOS URE TO MIST OR VAPORS OF
SULFURIC ACID MAY CAUSE EROSION OF THE TEETH.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:INHALATION: CAN CAUSE BURNS OF THE UPPER
RESPIRATORY TRACT AND LUNGS. SKIN CONTACT MAY CAUSE BURNS OR
LOCALIZED IRRITATION. EYE CONTACT: MAY CAUSE IRRITATION, CORNEAL
BURNS AND CONJUCTIVITIS. BLINDNES S MAY RESULT OR SEVERE OR
PERMANENT INJURY. INGESTION: ELECTROLYTE MAY CAUSE BURNS TO THE
MOUTH, ESOPHAGUS AND STOMACH.
Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF AILMENTS
OR WITH A PRE-EXISTING DISEASE INVOLVING THE RESPIRATORY TRACT OR
TEETH MAY BE AT INCREASED RISK FROM EXPOSURE.
First Aid
First Aid:INHALATION:REMOVE TO FRESH AIR. RESUSCITATE IF NOT BREATHING.
GET MEDICAL ATTENTION. EYES:IMMEDIATELY FLUSH WITH PLENTY OF WATER
FOR 15 MINUTES HOLDING EYELIDS OPEN. GET PROMPT MEDICAL ATTENTION.
SKIN :REMOVE CONTAMINATED CLOTHING. WASH WITH PLENTY OF WATER FOR
15 MINUTES. GET MEDICAL ADVICE. INGESTION:DO NOT INDUCE VOMITING.
GIVE NOTHING BY MOUTH IF UNCONSCIOUS. GET IMMEDIATE MEDICAL
ATTENTION.
Fire Fighting
Extinguishing Media:USE DRY CHEMICAL.
Fire Fighting Procedures:USE OF WATER IN EXTINGUISHING BURNING
BATTERIES MAY CAUSE SPATTERING DUE TO THE PRESENCE OF MOLTEN LEAD.
Unusual Fire/Explosion Hazard:AFTER ELECTROLYTE IS ADDED AND BATTERY IS
BEING CHARGED, HYDROGEN GAS IS PRODUCED. BATTERY MAY EXPLODE IF
HYDROGEN GAS TRAPPED INSIDE THE CASE SHOULD IGNITE.
Accidental Release
Spill Release Procedures:SHOULD A BATTERY BREAK OPEN, ISOLATE AREA.
ELECTROLYTE SHOULD BE ABSORBED WITH A NON-ORGANIC TYPE ABSORBENT
SUCH AS DRY SAND OR EARTH. AVOID DILUTION WITH WATER. LEAD SPILLED
FROM THE BATTERY SHOULD B E VACUUMED, DO NOT SWEEP OR USE
COMPRESSED AIR.
Neutralizing Agent:USE SODA ASH OR BAKING SODA TO NEUTRALIZE THE
ELECTROLYTE.
Handling
Handling and Storage Precautions:AVOID THE USE OF UNINSULATED TOOLS. IF
THEY ARE REQUIRED, TAKE CARE NOT TO ELECTRICALLY SHORT THE
TERMINALS. REMOVE METAL JEWELRY BEFORE SERVICING.
Other Precautions:UNDER NORMAL CONDITIONS OF USE, EXPOSURE TO LEAD OR
LEAD CONTAINING COMPOUNDS DOES NOT OCCUR. SHOULD A BATTERY BREAK
OPEN AND A LEAD SPILL OCCUR, PRECAUTIONS SHOULD BE TAKEN TO PREVENT
LEAD DUST FROM BECOMING AIR BORNE.
Exposure Controls
Respiratory Protection:UNDER NORMAL CONDITIONS OF USE, RESPIRATORY
PROTECTION IS NOT REQUIRED. HOWEVER, IF CONDITIONS ARISE THAT
REQUIRE THEIR USE, USE ONLY NIOSH/MSHA RESPIRATORS APPROVED FOR
DUST, FUME AND MIST.
Ventilation:BATTERY CHARGING AREAS MUST BE ADEQUATELY VENTILATED TO
PREVENT HAZARDOUS CONCENTRATIONS OF FLAMMABLE GAS OR ACID MIST.
Protective Gloves:RUBBER GLOVES APPROVED FOR SULFURIC ACID
Eye Protection:CHEMICAL SPLASH GOGGLES AND FACE SHIELD
Other Protective Equipment:EYE WASH STATION AND SAFETY SHOWER.
INDUSTRIAL-TYPE IMPERVIOUS WORK CLOTHING, BOOTS AND APRON AS
REQUIRED.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
IF THE BATTERY ROOM IS AIR CONDITIONED AS PART OF AN OVERALL BUILDING
SYSTEM, THE EXHAUST AIR FROM THE BATTERY ROOM SHOULD NOT BE
RETURNED TO THE AIR DISTRIBUTION SYSTEM. THE ROOM SHOULD HAVE ITS
OWN EXHAUST SYSTEM CONNECTED DIRECTLY TO OUTSIDE AIR. HYDROGEN GAS
IS LIGHTER THAN AIR AND DIFFICULT TO DETECT.
Chemical Properties
HCC:C1
Boiling Pt:B.P. Text:203F,95C
Vapor Pres:10
Vapor Density:>1
Spec Gravity:1.285
pH:>1
Evaporation Rate & Reference:<1
Solubility in Water:COMPLETE
Appearance and Odor:NO ODOR. BATTERY CASE IS PINK, OLIVE GREEN, BLACK.
ELECTROLYTE IS CLEAR LIQUID.
Stability
Stability Indicator/Materials to Avoid:YES
CONTACT OF ELECTROLYTE WITH ORGANIC MATERIAL. ALSO CONTACT OF LEAD
W/STRONG OXIDIZING AGENTS MAY LIBERATE HYDROGEN GAS.
Hazardous Decomposition Products:SULFURIC ACID MIST, SULFUR DIOXIDE AND
CARBON MONOXIDE MAY BE RELEASED WHEN ELECTROLYTE DECOMPOSES.
Disposal
Waste Disposal Methods:BOTH ELECTROLYTE AND SCRAP BATTERIES ARE
REGULATED HAZARDOUS WASTE. SCRAP BATTERIES CONTAIN MATERIALS WHICH
ARE RECYCLABLE AND MUST BE RETURNED TO AUTHORIZED RECYCLER.
ELECTROLYTE SHOULD BE HAULED TO A PERMITTED TREATMENT FACILITY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.